Similar to the two previous editions, this book can be used for an introductory as well as a more advanced course. Chapters begin with an introduction to switching converters and basic switching converter topologies. Entry level chapters continue with a discussion of resonant converters, isolated switching converters, and the control schemes of switching converters.
Skipping to chapters 10 and 11, the subject matter involves an examination of interleaved converters and switched capacitor converters to round out and complete the overview of switching converter topologies. More detailed chapters include the continuous time-modeling and discrete-time modeling of switching converters as well as analog control and digital control. Contributions from more than fifty leading experts spanning twelve different countries.
Add to cart. Sales tax will be calculated at check-out. Free Global Shipping. Genres: Physics. Historically, the evolution of power electronics has generally followed the semiconductor power device evolution. Power solid-state devices are the heart and soul of modern power electronics equipment.
Therefore, the age of power solidstate electronics is often called the second electronics revolution. Development of microelectronic controllers has made revolutionary advances in power electronics. Power electronics circuits are an integral part of all electronics equipments. For a duty cycle of 7. Converter appears as an ideal voltage source of 10V in series with a 5 ohm resistor.
This produces a symmetrical vo t and minimizes the harmonics. Additionally when there is a zero-crossing in the control voltage, the triangular waveform should have a negative derivative when the sinusoidal control waveform has a positive derivative as shown in the figure below.
Otherwise there may be underfined switchig instances if vcontrol has the same derivative as vtri. This may occur at overmodulation. For increasing power, it is also possible to parallel connect transistors in the half-bridge converter. Paralleling is demanding and normally a derating must be done to give room from unbalanced current sharing during both the switchings and the on-state intervals. For a sinusoidal control signal, this results in the output voltage waveform shown in Fig.
For each switching cycle, the output voltage is both positive and negative, depending on the duty cycle. The output voltage waveform is bipolar and hence the name for the modulation algorithm. V A,ph j! The new diagram is shown on the next page.
As can be seen in the figure above, the ovoltage across the inductor is positive for approximately one half of a period about 0. The two types of square are not much different from each other. Higher switching frequency gives even lower ripple. Note turns ratio correction 1 in the Io term.
Evaluating: N2 30 A The V supply is the 6 V output voltage reflected to the primary side of the transformer. The V supply represents the zener diode in breakdown. The magnetizing current will then flow as usual through the transformer primary only. The time tm is given by Eq. Resulting switch voltage versus time also plotted below.
Inductor current has an average value of 10 A and a ripple current zero average of 0. Diode currents plotted below. N2 During ton interval;. At full load, the filter works well. See the impedance plots below. L for each filter! It is fairly easy to design a regulator when the inductance is small compared to when the inductance is large.
So keeping the field at its maximum makes a short response time. In a PM motor there is no power supply for the field current and no field losses. From prob. It is the flux which is common for both the stator and the rotor windings. For a two-pole one pole-pair induction motor, the airgap field will rotate with f revolutions per s or! From eq. Lm I m 5 dt The equivalent circuit is like in Figure of the textbook.
The airgap flux is in phase with and proportional to the magnetizing current. This is due to the relative motion between stator and rotor, which affects the rate of variation of the flux linkage as seen by the rotor. The rotor current will then keep the same value when referred to the stator. Per phase power from the stator is Eag " I r " cos! The missing power is the electrical motor power Pem.
Flux is according to Eq. The magnetizing current is supplied from the grid as shown in Eq. When increasing the load torque, the Tem must also increase. Tem is produced by the resistive part of the rotor current, which then is almost proportional to the load torque.
Calculate and find the Vs1 resulting from the assumption at point 1 V 3. The angle between these two currents is! Then the rotor impedance is much less than Xm. Thus Xm can be omitted. Thus the rotor current will be less than calculated above, and also more resistive.
The torque per Ampere will increase. This means that the rotor currents are almost resistive. If Tem is kept below rated torque, the motor currents will also be below their rated values when the motor is started by a variable frequency converter.
To achieve this, the magnetizing current should be kept close to its rated value. Lm must increase when the converter frequency increases. Llr as calculated above. This is independent of f and Vs. Tr is the torque at rated speed which is lower than! Depending upon rated slip. It is therefore desirable to operate at the highest possible flux level, in order to get the maximum torque out of the machine, given the current limitation.
However, the flux cannot be increased above a certain limit, due to saturation of the magnetic iron, and the associated losses. Moreover, the flux cannot be increased above the limit defined by the available stator voltage, as stated by the equations above. Insulation limit of the stator windings is also of concern, when trying to operate the machine above its rated voltage.
Machines are usually designed to reach rated voltage at rated stator frequency, when the flux is controlled to its rated value.
A rule of thumb is to consider the slip small when it is less than twice its rated value. Therefore, optimum utilization is when losses are close to the rated value. This means that the rotor current should be kept constant, allowing for more torque availability.
The pull-out torque value decreased with the square of the operating frequency. Therefore, above a threshold frequency typically about two times the rated speed is no longer possible to keep the rotor current constant by linearly increasing the slip.
The slip 1 must be kept constant, resulting in an available torque proportional to 2 , as in g. This is possible if the machine is controlled by a converter with enough available voltage insulation is normally not a serious issue, since the windings must anyway be able to withstand the high voltage peaks resulting from the converter switching , provided that the cooling system is able to remove the additional heat caused by the increased iron losses.
So for counterclockwise direction phase sequence a-c-b. Ia will lead Van by and so forth. So it is preferable for resistive heating or melting load. Refer figure for rectifier and figure in textbook for inverter operation. Also high values of firing and extinction angle will cause consumption of large reactive power. So in case of grid voltage reduction the reactive power supplied by them reduces.
At this voltage currents for each conditions are 2.