Simplifies installation and UPS maintenance while minimizing space requirements. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Technical support Our experienced technical support engineers are available to answer your questions, giving you peace of mind knowing the help you need is there when you need it.

Easy to install Innovative design allows for fast, easy installation by almost anybody. User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR.

Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. LED Indicators Provide easy-to-read status of the unit and utility power conditions. Serial connectivity Provides management of the UPS via a serial port. Pure sine wave output on battery Simulates utility power to provide the highest degree of compatibility for active PFC power factor corrected servers and sensitive electronics.

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Temperature-compensated battery charging Prolongs battery life by regulating the charge voltage according to battery temperature. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced.

Power conditioning Protects connected loads from surges, spikes, lightning, and other power disturbances. Product Distribution Canada, United States. Technical Specifications Print. Other Output Voltages V. Topology Line interactive. Information shown on LCD display. Rack Mountable Allows additional runtime to be quickly added as needed V. Enhanced Intelligent Battery Management Temperature compensated charging extends life and advanced algorithms recommend replacement date.

The UPS can inform users which batteries need to be replaced in advance and auto detect when additional battery packs are added. It is also available in multiple languages. Backlight in different colors allows users to easily identify the UPS normal vs.

Best-in-class power density: More real power in watts,. Energy Star compliant. Operate without battery: Ability to immediately protect equipment when power returns after a complete discharge of the battery. Built-in energy meter: Measures energy use and displays UPS efficiency in various modes of operation for easy energy tracking.

Rack Mountable: Ability to easily mount into a rack or enclosure Smart-slot: Allows the ability to add in a network management card to manage and monitor the UPS remotely card sold separately Optional additional battery packs: can be added to increase runtime.

Over 15 different programmable settings including switched outlet group control allow for application specific settings, thresholds and notifications. Low operating and maintenance costs with high efficiency, proven reliability and intelligent battery management.

Ideal UPS smart-uups servers, point-of-sale, routers, switches, hubs and other Provides pure sine wave output which is recommended by server manufacturers using active power factor corrected PFC power supplies.

Peripherals by Rick Broida Oct 15, We delete comments that violate our policywhich we encourage you to read. Energy Efficiency Data Center Operation: Provides early-warning fault analysis ensuring proactive component replacement. Prolongs battery life by regulating the charge voltage according to battery temperature. Provides remote power management of the UPS over the specificatins. Ensures the product has been tested and approved to work safely with the connected service provider equipment and within the specified environment.

Ideal UPS for servers, point-of-sale, routers, switches, hubs and other Periodic battery self-test ensures early detection of a battery that needs to be replaced. Automatic restart of loads after UPS shutdown. Provides early-warning fault analysis on batteries enabling timely preventive maintenance.

Peripherals by Lori Grunin Aug 20, Smarr-ups time with easy and convenient remote accessibility. Intelligent battery management Maximizes battery performance, life, and reliability through intelligent, precision charging. Automatic self-test Periodic battery self-test ensures early detection of a battery that needs to be replaced. Boost and Trim Automatic Voltage Regulation AVR Gives higher application availability by correcting low and high voltage conditions without using the battery not available on all models.

Automatic restart of loads after UPS shutdown Automatically starts up the connected equipment upon the return of utility power. Resettable circuit breakers Enables a quick recovery from overload events. Battery failure notification Provides early-warning fault analysis on batteries enabling timely preventive maintenance.

User-replaceable batteries Increases availability by allowing a trained user to perform upgrades and replacements of the batteries reducing Mean Time to Repair MTTR. Hot-swappable batteries Ensures clean, uninterrupted power to protected equipment while batteries are being replaced. Predictive failure notification. Provides early-warning fault analysis ensuring proactive component replacement. Technical Specifications Print.

Max Configurable Power Watts 1. Topology Line interactive. Waveform type Sine wave. Input voltage range for main operations 75 - Adjustable, 82 - V. Number of Power Cords 1. Maximum Short Circuit Withstand Icw Battery type Lead-acid battery. Typical recharge time 3hour s. Nominal Battery Voltage 48 V. Expected Battery Life years 3 - 5.

RBC Quantity 1.